Edition-Specific Guides

Use these expandable sections for the platform deployed with your edition.

📦 HR-EDC-4U-NUC – VMware / Proxmox
  • Reference image stored on the included USB recovery drive.
  • BIOS settings: enable VT-d, disable secure boot, set boot order to NVMe.
  • Import Proxmox cluster template and update node hostnames to match site naming.
🔶 HR-EDC-4U-HR01-2 – StorMagic SvHCI
  • Use the StorMagic deployment wizard and select the HR01-2 profile.
  • Apply license keys provided by customer. HiveRadar does not manage software entitlement.
  • Validate witness connectivity over the management VLAN (default 192.168.10.0/24).
🟣 HR-EDC-4U-HR01-4 – High Availability
  • Follow the 4-node stretch cluster playbook supplied by the software vendor.
  • Configure two-node fault domains (1/3 and 2/4) for resilience.
  • Document quorum design in the deployment record for support alignment.

Partner Notes

  • Capture screenshots of all licensing activations for the quality assurance package.
  • Upload final configuration backups to the partner portal ticket.